Manual Part # 800-1070-001, Rev112012 Page 8 of 16
Calibration
1. Check to be sure installation of all parts is complete, all fasteners are
secure and the Encoder is plugged into the Readout.
2. Cut a small part (approximately 8 inches) using the stop. DO NOT MOVE
THE STOP UNTIL THIS PROCEDURE IS COMPLETED.
3. Measure the length of the part with the most precise measuring tool you
have available (preferably digital calipers).
4. Press the Datum key to ‘zero’ the readout, then press and hold the +
(PLUS) key to change the reading until the length you just measured is
shown (The longer the + key is held down, the faster the readout will scroll).
This adjustment should be made in a decimal (inches or mm) mode for the
best accuracy.
5. When the correct reading is reached, lock the readout if desired. This
prevents accidentally re-zeroing during normal use.
See Section 3: Readout Lock Mode
Maintenance
The fence extrusion should be cleaned of debris periodically. Do not use any
liquid lubricants on the scale, as this may impede the encoder's ability to
operate properly and attract other contaminants to the scale.
If the stop becomes difficult to move, and the fence and scale have both been
cleaned, the plastic wing may need adjustment:
a. Position the wing to hold the locking mechanism of the stop in the center
of the extrusion slot.
b. The position of the wing can be adjusted after removing the plastic guide
clip and loosening the socket screws (using a 3/16" hex wrench) which
sandwich the wing between the stop and the aluminum block. The wing
is adjusted properly when the weight of the stop is supported by the
wing and the locking mechanism
does not rub on the extrusion.
The readout should be cleaned periodically
with compressed air to remove any dust on
the lens and keys. All fasteners should occasionally be checked for tightness.