Accurate Technology DigiStop Page 15 of 16
Programming Parameters
The Digi-Stop readout programming parameters are listed below.
Values in [ ] are the available range of values that can be entered for that
parameter. Factory defaults are shown in Bold Red.
Pr 1 Datum Key [0 to + 999.999in] or [0 to +9999.99mm]
The programmed value that will be recalled whenever the DATUM key is
pressed during normal operation. Default = 0.00
Pr 2 Reverse Readings [0 or 1]
This parameter controls the direction of travel (positive vs. negative) when the
stop is moved. Default = 0
Pr 3 Key Lockout [0 or 1]
This parameter controls the operation of the +, - and DATUM keys.
If enabled, (set to 1), these keys will not function and the LOCK symbol will
appear on the display. This prevents accidental changes when pressing these
keys during normal operation. Default = 0
Pr 4 Readout Resolution [1, 2, 3 ]
This parameter sets the number of places to the right of the decimal point on
the readout. Default = 2
A value of 1 Low - will display x.x.
A value of 2 Normal -will display x.xx
A value of 3 High - will display x.xxx
Frequently Asked Questions
What F/W (Firmware) version do I have?
The readout will display the firmware version on power up.
What does no Enc mean?
If the encoder cable is unplugged from the readout , no Enc will appear
on the display. To clear: Be sure the encoder is on the scale and
plugged into the readout.
The battery clips seem to be very loose. Is this normal?
Yes. DO NOT attempt to bend these clips or wedge anything between
them and the case. These clips are designed to expand when the two
case halves are screwed together.
The readings are “backwards”?
You can change reading direction of the Digi-Stop by changing the
value of Programming Parameter Pr 2.
What does b FAIL mean?
When the readout displays this message it means the battery voltage
has dropped to a level where reliable operation is no longer possible.
Install new batteries to clear this message.
What does P FAIL mean?
When the readout displays this message it means the battery voltage
has dropped to a level where reliable programming is not possible.
Install new batteries to clear this message.