ProScale RF Receiver User Manual Page 11 of 17
described below in an outline format. For detailed information regarding the
ProRF communication format, review the document entitled: “ProRF System
Definition and Communications Protocol Architecture” available from Accurate
Technology, Inc.
Measurement Sample
Receiver’s
Address
[255] (Base)
Sender’s
Address
[1 –254]
Command
Header
[‘A’]
RSSI
Value
[‘1’ – ‘7’]
1 = low
signal
7 = high
signal
Message
Packet
ID
[0 – 255]
Number of
Data Bytes
[13]
Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6
Module
Type
[1]
Module
Status
[0 – 0xFF]
Encoder
Status
[0 – 0xFF]
Data
Capture
Latch
[0 – 0xFF]
Units of
Operation
[0] = mm.
[1] = in.
ASCII Position
Data
[‘0’ – ‘9’ ‘.’ ‘-‘]
Byte 7 Byte 8 Byte 9 Byte 10 Byte 11 Bytes 12 - 19
Note: In the ProScale RF emulation mode, bytes 7 through 10 of the
Measurement Sample message are fixed at 1, 0, 1, and 1 respectively.
Delete Previous Measurement Sample
Receiver’s
Address
[255]
Sender’s
Address
[1-254]
Command
Header
[‘I’]
RSSI
Value
[‘1’ – ‘7’]
1 = low
signal
7 = high
signal
Message
Packet
ID
[0 – 255]
Number of
Data Bytes
[0]
Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6